FLIR A50/A70 Smart Sensor
FLIR A50/A70 Smart Sensor
FLIR A50/A70 Smart Sensor
FLIR A50/A70 Smart Sensor
Model :A50 51° + Smart Sensor Configuration (Advanced)
Featured Information
Digital I/O Connector Type :
M12 12-pin A-coded, Male (shared with external power)
Digital Inputs :
2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 V
Digital Output Purpose :
• As a function of alarm, output to external device • Fault (NC)
A50 51° + Smart Sensor Configuration (Advanced)
FLIR A50/A70 Smart Sensor
SPECIFICATIONS
- Digital I/O Connector Type : M12 12-pin A-coded, Male (shared with external power)
- Digital Inputs : 2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 V
- Digital Output Purpose : • As a function of alarm, output to external device • Fault (NC)
- Digital Outputs : 3x opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as Fault output (NC)
- Encoding : Video stream: H.264, MPEG4, or MJPEG Radiometric stream: Compressed JPEG-LS, FLIR radiometric
- Ethernet Interface : Wired, Wi-Fi (optional)
- WiFi : Optional feature purchased separately. RP-SMA, female connector
- EMC : • ETSI EN 301 489-1 (radio) • ETSI EN 301 489-17 (radio) • EN 61000-4-8 (magnetic field) • FCC 47 CFR Part 15 Class B (emission US) • ISO 13766-1 (EMC - Earth-moving and building construction machinery) • EN ISO 14982 (EMC - Agricultural and forestry machinery)
- f-number : 1.4
- Image Fequency : 30Hz
COMMUNICATION & DATA STORAGE
- Digital I/O Connector Type : M12 12-pin A-coded, Male (shared with external power)
- Digital I/O Isolation Voltage : 500 VRMS
- Digital Input Purpose : NUC, NUC disable, alarm
- Digital Inputs : 2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 V
- Digital Output Purpose : • As a function of alarm, output to external device • Fault (NC)
- Digital Outputs : 3x opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as Fault output (NC)
- Encoding : Video stream: H.264, MPEG4, or MJPEG Radiometric stream: Compressed JPEG-LS, FLIR radiometric
- Ethernet : For control, result, image, and power
- Ethernet Communication : TCP/IP socket-based FLIR proprietary
- Ethernet Connector Type : M12 8-pin X-coded, female; RP-SMA, female
IMAGING & OPTICAL
- Contrast Enhancement : FSX® / Histogram equalization (IR only)
- Detector Pitch : 17 µm
- Field of View (FOV) : 51° × 39°
- f-number : 1.4
- Focal Length : 8.2 mm (0.32 in)
- Focal Plane Array (FPA) : Uncooled microbolometer
- Focus : Fixed, adjustable with included tool
- Image Fequency : 30Hz
- IR Resolution : 464 × 348
- Minimum Focus Distance : 0.2 m (0.66 ft)
MEASUREMENT & ANALYSIS
- Accuracy : ±2°C (±3.6°F) or ±2% of reading, for ambient temperature 15°C–35°C (59°F–95°F) and object temperature above 0°C (32°F)
- Alarm Functions : 10 Spotmeters 10 Boxes and Mask polygons (total number) 3 Deltas (difference any value/reference/external lock) 2 Isotherm (above/below/interval) 2 Iso-coverage 1 Reference temperature 2 Lines 1 Polyline
- Alarm Output : Digital out E-mail (SMTP) (push) EtherNet/IP (pull) File transfer (FTP) (push) Modbus TCP Client (push) Modbus TCP Server (pull) MQTT (push) ONVIF events (push) Query over RESTful API (pull) Store image or video
- Atmospheric Transmission Correction : Based on inputs of distance, atmospheric temperature, and relative humidity
- Automatic Hot & Cold Detection : Max./min. temperature value and position shown within Box
- Measurement Corrections : Global object parameters; local parameters per analyze function; external Black-body correction
- Measurement Presets : Yes
- Measurement Tools : 10 spotmeters, 10 boxes and mask polygons (total number), 3 Deltas (difference any value/reference/external lock), 2 isotherms (above/below/interval), 2 iso-coverage, 1 reference temperature, 2 lines, 1 polyline
- Object Temperature Range : –20 to 175°C (–4 to 347°F) 175 to 1000°C (347 to 1832°F)
ENVIRONMENTAL & CERTIFICATIONS
- Corrosion : • ISO 12944 C4 G or H • EN60068-2-11
- EMC : • ETSI EN 301 489-1 (radio) • ETSI EN 301 489-17 (radio) • EN 61000-4-8 (magnetic field) • FCC 47 CFR Part 15 Class B (emission US) • ISO 13766-1 (EMC - Earth-moving and building construction machinery) • EN ISO 14982 (EMC - Agricultural and forestry machinery)
- Encapsulation : IEC 60529 and IP66
- Humidity (Operating and Storage) : IEC 60068-2-30/24 hours, 95% relative humidity, 25–40°C (77–104°F)/2 cycles EN60068-2-38
- Operating Temperature Range : –20 to 50°C (–4 to 122°F) Bottom cooling plate is needed in temperatures above 40°C (104°F). Maximum internal temperature sensor: 70°C (158°F)
- Radio Spectrum : • FCC 47 CFR Part 15 Class C (2.4 GHz band US) • FCC 47 CFR Part 15 Class E (5 GHz band US) • RSS-247 (2.4 GHz and 5 GHz band Canada) • ETSI EN 300 328 V2.1.1 (2.4 GHz band EU) • ETSI EN 301 893 V2.1.1 (5 GHz band EU)
- Shock : IEC 60068-2-27, 25 g
- Tripod Mounting : 4 x M2.5 direct into camera or 4x 10-32 UNF onto bottom cooling plate
- Vibration : • IEC 60068-2-6, 0.15 mm at 10–58 Hz and 2 g at 58–500 Hz, sinusoidal • IEC 61373 Cat 1 (Railway)
USER INTERFACE
- Web Interface : Yes
- Thermal Sensitivity/NETD : <35mK
- Accuracy : ±2°C (±3.6°F) or ±2% of reading, for ambient temperature 15°C–35°C (59°F–95°F) and object temperature above 0°C (32°F)
- Alarm Functions : 10 Spotmeters 10 Boxes and Mask polygons (total number) 3 Deltas (difference any value/reference/external lock) 2 Isotherm (above/below/interval) 2 Iso-coverage 1 Reference temperature 2 Lines 1 Polyline
- Alarm Output : Digital out E-mail (SMTP) (push) EtherNet/IP (pull) File transfer (FTP) (push) Modbus TCP Client (push) Modbus TCP Server (pull) MQTT (push) ONVIF events (push) Query over RESTful API (pull) Store image or video
- Ethernet Interface : Wired, Wi-Fi (optional)
- Ethernet Power : Power over Ethernet, PoE IEEE 802.3af class 3
- Ethernet Protocols : • EtherNet/IP • IEEE 1588 • Modbus TCP • MQTT • SNMP • TCP, UDP, SNTP, RTSP, RTP, HTTP, HTTPS, ICMP, IGMP, sftp (server), FTP (client), SMTP, DHCP, MDNS (Bonjour), uPnP
- Ethernet Standard : IEEE 802.3
- Ethernet Type : 1000 Mbps
- Image Storage : NA
- Multicast : Yes
- RS-232 : M8 A-coded, male connector
- WiFi : Optional feature purchased separately. RP-SMA, female connector
- MSX : Yes, included in visual camera option
- Overlay : Without
- Radiometric IR Video Streaming : RTSP protocol
- Readout : No measurements readouts, only streamed video
- Spectral Range : 7.5–14 µm
- Streaming Resolution : RTSP Video stream 0: 464 × 348 pixels RTSP Video stream 1: 1280 × 960 pixels Radiometric stream: 464 × 348 pixels
- Thermal Sensitivity/NETD : <35mK
- Video Streaming : RTSP protocol
- Visible Camera : Optional accessory
GENERAL
- Base Mounting : 4 x M2.5 direct into camera or 4x 10-32 UNF onto bottom cooling plate
- Housing Material : Aluminium
- Size (L x W x H) 107 × 67 × 57 mm (4.21 × 2.64 × 2.24 in)
- Weight : 519g (1.14lb) without bottom cooling plate
POWER
- External Power Operation : 24/48 V DC 8 W max
- External Voltage : Allowed range 18–56 V DC
- Digital Input Purpose : NUC, NUC disable, alarm
- Power Consumption : • 7.5 W at 24 V DC typical • 7.8 W at 48 V DC typical • 8.1 W at 48 V PoE typical
A50 51° + Smart Sensor Configuration (Advanced)
FLIR A50/A70 Smart Sensor
FLIR A50 and A70 smart sensor cameras are ideal for users who want built-in, on-camera analytics and alarm capabilities for condition monitoring and early fire detection applications. With options for Wi-Fi, an integrated visual camera, and ONVIF S compatibility, FLIR A50/A70 cameras are a flexible, configurable solution to meet the unique needs of automation customers across a broad range of industries. When used as a system component for cloud and Industrial Internet of Things (IIoT) solutions, A50/A70 cameras can help companies protect assets, improve safety, maximize uptime, and minimize maintenance costs.