Digital I/O Connector Type :
M12 12-pin A-coded, Male (shared with external power)
Digital Inputs :
2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 V
Digital Output Purpose :
• As a function of alarm, output to external device • Fault (NC)
Product thumb
A50 51° + Smart Sensor Configuration (Advanced)
FLIR A50/A70 Smart Sensor

SPECIFICATIONS

  • Digital I/O Connector Type :  M12 12-pin A-coded, Male (shared with external power)
  • Digital Inputs :  2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 V
  • Digital Output Purpose :  • As a function of alarm, output to external device • Fault (NC)
  • Digital Outputs :  3x opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as Fault output (NC)
  • Encoding :  Video stream: H.264, MPEG4, or MJPEG Radiometric stream: Compressed JPEG-LS, FLIR radiometric
  • Ethernet Interface :  Wired, Wi-Fi (optional)
  • WiFi :  Optional feature purchased separately. RP-SMA, female connector
  • EMC :  • ETSI EN 301 489-1 (radio) • ETSI EN 301 489-17 (radio) • EN 61000-4-8 (magnetic field) • FCC 47 CFR Part 15 Class B (emission US) • ISO 13766-1 (EMC - Earth-moving and building construction machinery) • EN ISO 14982 (EMC - Agricultural and forestry machinery)
  • f-number :  1.4
  • Image Fequency :  30Hz

COMMUNICATION & DATA STORAGE

  • Digital I/O Connector Type :  M12 12-pin A-coded, Male (shared with external power)
  • Digital I/O Isolation Voltage :  500 VRMS
  • Digital Input Purpose :  NUC, NUC disable, alarm
  • Digital Inputs :  2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 V
  • Digital Output Purpose :  • As a function of alarm, output to external device • Fault (NC)
  • Digital Outputs :  3x opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as Fault output (NC)
  • Encoding :  Video stream: H.264, MPEG4, or MJPEG Radiometric stream: Compressed JPEG-LS, FLIR radiometric
  • Ethernet :  For control, result, image, and power
  • Ethernet Communication :  TCP/IP socket-based FLIR proprietary
  • Ethernet Connector Type :  M12 8-pin X-coded, female; RP-SMA, female

IMAGING & OPTICAL

  • Contrast Enhancement :  FSX® / Histogram equalization (IR only)
  • Detector Pitch :  17 µm
  • Field of View (FOV) :  51° × 39°
  • f-number :  1.4
  • Focal Length :  8.2 mm (0.32 in)
  • Focal Plane Array (FPA) :  Uncooled microbolometer
  • Focus :  Fixed, adjustable with included tool
  • Image Fequency :  30Hz
  • IR Resolution :  464 × 348
  • Minimum Focus Distance :  0.2 m (0.66 ft)

MEASUREMENT & ANALYSIS

  • Accuracy :  ±2°C (±3.6°F) or ±2% of reading, for ambient temperature 15°C–35°C (59°F–95°F) and object temperature above 0°C (32°F)
  • Alarm Functions :  10 Spotmeters 10 Boxes and Mask polygons (total number) 3 Deltas (difference any value/reference/external lock) 2 Isotherm (above/below/interval) 2 Iso-coverage 1 Reference temperature 2 Lines 1 Polyline
  • Alarm Output :  Digital out E-mail (SMTP) (push) EtherNet/IP (pull) File transfer (FTP) (push) Modbus TCP Client (push) Modbus TCP Server (pull) MQTT (push) ONVIF events (push) Query over RESTful API (pull) Store image or video
  • Atmospheric Transmission Correction :  Based on inputs of distance, atmospheric temperature, and relative humidity
  • Automatic Hot & Cold Detection :  Max./min. temperature value and position shown within Box
  • Measurement Corrections :  Global object parameters; local parameters per analyze function; external Black-body correction
  • Measurement Presets :  Yes
  • Measurement Tools :  10 spotmeters, 10 boxes and mask polygons (total number), 3 Deltas (difference any value/reference/external lock), 2 isotherms (above/below/interval), 2 iso-coverage, 1 reference temperature, 2 lines, 1 polyline
  • Object Temperature Range :  –20 to 175°C (–4 to 347°F) 175 to 1000°C (347 to 1832°F)

ENVIRONMENTAL & CERTIFICATIONS

  • Corrosion :  • ISO 12944 C4 G or H • EN60068-2-11
  • EMC :  • ETSI EN 301 489-1 (radio) • ETSI EN 301 489-17 (radio) • EN 61000-4-8 (magnetic field) • FCC 47 CFR Part 15 Class B (emission US) • ISO 13766-1 (EMC - Earth-moving and building construction machinery) • EN ISO 14982 (EMC - Agricultural and forestry machinery)
  • Encapsulation :  IEC 60529 and IP66
  • Humidity (Operating and Storage) :  IEC 60068-2-30/24 hours, 95% relative humidity, 25–40°C (77–104°F)/2 cycles EN60068-2-38
  • Operating Temperature Range :  –20 to 50°C (–4 to 122°F) Bottom cooling plate is needed in temperatures above 40°C (104°F). Maximum internal temperature sensor: 70°C (158°F)
  • Radio Spectrum :  • FCC 47 CFR Part 15 Class C (2.4 GHz band US) • FCC 47 CFR Part 15 Class E (5 GHz band US) • RSS-247 (2.4 GHz and 5 GHz band Canada) • ETSI EN 300 328 V2.1.1 (2.4 GHz band EU) • ETSI EN 301 893 V2.1.1 (5 GHz band EU)
  • Shock :  IEC 60068-2-27, 25 g
  • Tripod Mounting :  4 x M2.5 direct into camera or 4x 10-32 UNF onto bottom cooling plate
  • Vibration :  • IEC 60068-2-6, 0.15 mm at 10–58 Hz and 2 g at 58–500 Hz, sinusoidal • IEC 61373 Cat 1 (Railway)

USER INTERFACE

  • Web Interface :  Yes

  • Thermal Sensitivity/NETD :  <35mK
  • Accuracy :  ±2°C (±3.6°F) or ±2% of reading, for ambient temperature 15°C–35°C (59°F–95°F) and object temperature above 0°C (32°F)
  • Alarm Functions :  10 Spotmeters 10 Boxes and Mask polygons (total number) 3 Deltas (difference any value/reference/external lock) 2 Isotherm (above/below/interval) 2 Iso-coverage 1 Reference temperature 2 Lines 1 Polyline
  • Alarm Output :  Digital out E-mail (SMTP) (push) EtherNet/IP (pull) File transfer (FTP) (push) Modbus TCP Client (push) Modbus TCP Server (pull) MQTT (push) ONVIF events (push) Query over RESTful API (pull) Store image or video

  • Ethernet Interface :  Wired, Wi-Fi (optional)
  • Ethernet Power :  Power over Ethernet, PoE IEEE 802.3af class 3
  • Ethernet Protocols :  • EtherNet/IP • IEEE 1588 • Modbus TCP • MQTT • SNMP • TCP, UDP, SNTP, RTSP, RTP, HTTP, HTTPS, ICMP, IGMP, sftp (server), FTP (client), SMTP, DHCP, MDNS (Bonjour), uPnP
  • Ethernet Standard :  IEEE 802.3
  • Ethernet Type :  1000 Mbps
  • Image Storage :  NA
  • Multicast :  Yes
  • RS-232 :  M8 A-coded, male connector
  • WiFi :  Optional feature purchased separately. RP-SMA, female connector

  • MSX :  Yes, included in visual camera option
  • Overlay :  Without
  • Radiometric IR Video Streaming :  RTSP protocol
  • Readout :  No measurements readouts, only streamed video
  • Spectral Range :  7.5–14 µm
  • Streaming Resolution :  RTSP Video stream 0: 464 × 348 pixels RTSP Video stream 1: 1280 × 960 pixels Radiometric stream: 464 × 348 pixels
  • Thermal Sensitivity/NETD :  <35mK
  • Video Streaming :  RTSP protocol
  • Visible Camera :  Optional accessory

GENERAL

  • Base Mounting :  4 x M2.5 direct into camera or 4x 10-32 UNF onto bottom cooling plate
  • Housing Material :  Aluminium
  • Size (L x W x H)  107 × 67 × 57 mm (4.21 × 2.64 × 2.24 in)
  • Weight :  519g (1.14lb) without bottom cooling plate

POWER

  • External Power Operation :  24/48 V DC 8 W max
  • External Voltage :  Allowed range 18–56 V DC
  • Digital Input Purpose :  NUC, NUC disable, alarm
  • Power Consumption :  • 7.5 W at 24 V DC typical • 7.8 W at 48 V DC typical • 8.1 W at 48 V PoE typical
Product thumb
A50 51° + Smart Sensor Configuration (Advanced)
FLIR A50/A70 Smart Sensor

FLIR A50 and A70 smart sensor cameras are ideal for users who want built-in, on-camera analytics and alarm capabilities for condition monitoring and early fire detection applications. With options for Wi-Fi, an integrated visual camera, and ONVIF S compatibility, FLIR A50/A70 cameras are a flexible, configurable solution to meet the unique needs of automation customers across a broad range of industries. When used as a system component for cloud and Industrial Internet of Things (IIoT) solutions, A50/A70 cameras can help companies protect assets, improve safety, maximize uptime, and minimize maintenance costs.